2026 Realistic GuideTorrent INST1-V8 Dumps PDF - 100% Passing Guarantee Free BICSI INST1-V8 Exam Questions and Answer NEW QUESTION # 60 What grade of plywood is recommended for use with ICT systems? A. B/C B. A/C C. C/D D. A/D Answer: B NEW QUESTION # 61 Which of the following are typically used to support cables between a cable tray and work area outlets? A. Innerduct B. Pipe hanger C. Trapeze D. [...]

2026 Realistic GuideTorrent INST1-V8 Dumps PDF - 100% Passing Guarantee [Q60-Q82]

Share

2026 Realistic GuideTorrent INST1-V8 Dumps PDF - 100% Passing Guarantee

Free BICSI INST1-V8 Exam Questions and Answer

NEW QUESTION # 60
What grade of plywood is recommended for use with ICT systems?

  • A. B/C
  • B. A/C
  • C. C/D
  • D. A/D

Answer: B


NEW QUESTION # 61
Which of the following are typically used to support cables between a cable tray and work area outlets?

  • A. Innerduct
  • B. Pipe hanger
  • C. Trapeze
  • D. J-Hook

Answer: D


NEW QUESTION # 62
What is the bend radius requirement for optical fiber cable when the cable is at rest?

  • A. 15 times the cables outside diameter
  • B. 20 times the cables outside diameter
  • C. 10 times the cables outside diameter

Answer: C


NEW QUESTION # 63
Which type of cabling is installed between a main cross connect and a horizontal cross connect?

  • A. Horizontal
  • B. Second-level backbone
  • C. First-level backbone

Answer: C


NEW QUESTION # 64
If you are working on a catwalk, you are required to wear _____?

  • A. Full body harness and two lanyards
  • B. Nothing, your fine on the catwalk
  • C. Safety belt

Answer: A


NEW QUESTION # 65
What is the required physical topology for a SCS?

  • A. Ring
  • B. Star
  • C. Tree
  • D. Bus

Answer: B


NEW QUESTION # 66
What is the maximum allowable horizontal cable length?

  • A. 90 m (295')
  • B. 30 m (100')
  • C. 50 m (164')
  • D. 10 m (33 ')

Answer: A


NEW QUESTION # 67
Which of the following tools is a low-cost cable verifier that can be used to test for opens, shorts, crossed pairs, and miswires in 4- pair cables?

  • A. Qualification tester
  • B. Telephone test set
  • C. TDR
  • D. Wire map tester

Answer: D


NEW QUESTION # 68
Which of the following attachment methods does BICSI recommend for attaching coaxial connectors to coaxial cable?

  • A. Crimp
  • B. Push-on
  • C. Compression
  • D. Screw-on

Answer: C


NEW QUESTION # 69
What is the minimum number of consolidation points that should serve an open office furniture cluster?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C


NEW QUESTION # 70
Light pulses in optical fiber cables are subjected to a loss in power as the light pulses travel along the optical fiber. Which of the following terms is used to describe this phenomenon?

  • A. Grounding
  • B. Frequency
  • C. Attenuation
  • D. Crosstalk

Answer: C


NEW QUESTION # 71
You are pre-terminating cable. Where should the labels be placed?

  • A. Near end
  • B. Far end
  • C. Both ends

Answer: C


NEW QUESTION # 72
What is the minimum inside bend radius for balanced twisted pair (multi-pair) cable?

  • A. 10 times the outside cable diameter
  • B. 25 mm (1")
  • C. 50 mm (2")
  • D. 6 times the outside cable diameter

Answer: A


NEW QUESTION # 73
Which of the following is used to connect cabinets to the nearest SBB?

  • A. RBB
  • B. BBC
  • C. TEBC
  • D. TBB

Answer: C


NEW QUESTION # 74
What is the primary purpose of the telecommunications bonding infrastructure?

  • A. Equalize potentials between metallic surfaces and equipment within entrance facilities
  • B. Improve the performance of the installed telecommunications equipment
  • C. Provide backup power to the telecommunications equipment when primary power to the equipment fails.

Answer: A


NEW QUESTION # 75
Which phase of testing includes documenting the test results?

  • A. Phase 1
  • B. Phase 2
  • C. Phase 3

Answer: C


NEW QUESTION # 76
Volts are measurement of _______?

  • A. Electrical pressure
  • B. Sound waves
  • C. Electromagnetic radiation
  • D. Light reflection

Answer: A


NEW QUESTION # 77
Which of the following items may be used as a substitute device for a pulling eye?

  • A. Innerduct
  • B. D rings
  • C. Fan-out kit
  • D. Wire mesh grip

Answer: D


NEW QUESTION # 78
Which of the following tend to cause sheath damage during cable pulling?

  • A. RMC/IMC
  • B. FMC/FMT
  • C. EMT/ENT

Answer: B


NEW QUESTION # 79
Which of the following fire ratings refers to the time period that the unexposed surface of a firestop assembly does not exceed 180 degrees C (325 degrees F) above its initial temperature?

  • A. E rating
  • B. FH rating
  • C. S rating
  • D. FT rating

Answer: D


NEW QUESTION # 80
Which of the following steps should be performed first when terminating a coaxial cable?

  • A. Verify connector type
  • B. Cut the cable
  • C. Fold back the braiding
  • D. Strip the cable

Answer: A


NEW QUESTION # 81
What is the characteristic impedance of Series-6 coaxial cable?

  • A. 25 ohms
  • B. 75 ohms
  • C. 50 ohms
  • D. 100 ohms

Answer: B